FOR SALE

Samsung LA4-18B Broadband Linear Array Transducer – Tested & Guaranteed

Probesources logo
Probesources•Verified
Trader
•Based in Hong Kong, 🇭🇰 HK
•Website not published
•Pricing available on inquiry

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.

Product Details

MOQ
1
Model
LA4-18B
Supplier status
Pricing available on inquiry
Description

roduct Description

The Samsung LA4-18B Original Used Ultrasound Probe is a premium high-frequency broadband linear array transducer engineered for superior superficial imaging and highly detailed diagnostic examinations. Operating within a 4–18 MHz broadband frequency range, the LA4-18B delivers excellent near-field resolution, strong Doppler sensitivity, and stable imaging performance for demanding clinical applications.

The probe is widely recognized for its excellent performance in vascular and musculoskeletal imaging, while also providing precise visualization of thyroid, breast, tendon, ligament, and other superficial anatomical structures. The 37 mm linear footprint and broadband architecture allow clinicians to achieve consistent image clarity and reliable diagnostic confidence.

For hospitals, imaging centers, distributors, and ultrasound service providers, replacing a high-frequency probe often comes with critical operational concerns.

Common customer pain points

✓ Hidden crystal defects causing image artifacts or dropout
✓ Inconsistent Doppler performance after installation
✓ Unstable image quality during superficial examinations
✓ Compatibility uncertainty with existing ultrasound systems
✓ Equipment downtime affecting patient workflow
✓ International transportation risks for sensitive probes

To reduce these risks, every Samsung LA4-18B supplied by us undergoes strict inspection and complete functionality verification before shipment.

Each unit is tested for:

✓ Crystal performance and image uniformity verification
✓ Connector and cable integrity inspection
✓ Housing condition evaluation
✓ Doppler functionality testing
✓ Stable operational performance verification
✓ Complete imaging functionality testing

To eliminate purchasing uncertainty, actual testing images or testing videos are provided before shipment, allowing customers to verify image quality and product condition before delivery.

The Samsung LA4-18B is commonly used for:

✓ Vascular examinations
✓ Musculoskeletal (MSK) imaging
✓ Thyroid imaging
✓ Breast examinations
✓ Small-parts imaging
✓ Tendon and ligament evaluation
✓ Peripheral vascular assessment
✓ Superficial tissue imaging

Compatible systems include:

  • Samsung RS80A
  • Samsung RS85
  • Samsung RS80 EVO
  • Samsung WS80A
  • Samsung HS60
  • Samsung HS70
  • Samsung HS70A
  • Samsung HERA W9
  • Samsung HERA W10

Compatibility may vary according to software versions and regional configurations. Compatibility confirmation can be provided before ordering.

With more than 20 years of ultrasound probe industry experience, we understand that minimizing downtime and reducing purchasing risks directly affects customer operations. Therefore we provide:

✓ 60-Day Warranty
✓ 7-Day Free Replacement or Return Policy
✓ Fast Worldwide Shipping within 2–4 Business Days

Technical Specifications

ParameterSpecification
Product NameSamsung LA4-18B Ultrasound Probe
ConditionOriginal Used
BrandSamsung Medison
ModelLA4-18B
Probe TypeBroadband Linear Array Transducer
Frequency Range4–18 MHz
Probe TechnologyHigh-Frequency Broadband Linear Imaging
Aperture37 mm
ApplicationsVascular, MSK, Thyroid, Breast, Small Parts
Clinical UseHigh-Resolution Superficial Imaging
Imaging TypeLinear Imaging
Doppler CapabilityYes
Compatible SystemsRS80A, RS85, RS80 EVO, WS80A, HS60, HS70, HS70A, HERA W9/W10
Imaging PerformanceStable and Verified
Probe InspectionCrystal, Connector, Cable, Housing, Imaging Test
Test VerificationTesting Images or Videos Provided Before Shipment
Warranty60 Days
Return Policy7-Day Free Replacement or Return
Delivery Time2–4 Business Days
Shipping MethodDHL / FedEx / UPS / International Express
PackagingProfessional Medical Export Packaging
Quality Control100% Tested Before Shipment

The 4–18 MHz frequency range, linear-array design, and compatibility with Samsung RS/HS/HERA platforms are consistently referenced across multiple technical and reseller sources.

Frequently Asked Questions

What is the Minimum Order Quantity (MOQ)?

MOQ: 1 Piece

Suitable for hospitals, imaging centers, distributors, repair providers, and ultrasound service companies.

How secure is the packaging?

All probes are packed using professional medical export-standard protection:

✓ Anti-static packaging materials
✓ Reinforced foam cushioning
✓ Multi-layer shock-absorbing protection
✓ Durable export-grade outer cartons

How safe is the shipping process?

We use internationally trusted logistics providers:

✓ DHL
✓ FedEx
✓ UPS
✓ Other secure international express services

Tracking information is provided with every shipment to ensure safe and reliable worldwide delivery.

Why Choose Us?

✓ More than 20 years of ultrasound probe industry experience
✓ Original quality products with strict testing procedures
✓ Actual testing images/videos before shipment
✓ Fast worldwide shipping within 2–4 business days
✓ Stable and verified imaging performance
✓ 60-day warranty + 7-day replacement/return support
✓ Professional technical and after-sales support
✓ Reduced equipment downtime and lower purchasing risks for customers

Send inquiry

Be specific about quantity, destination, timeline, and any critical specs.

For faster WhatsApp or phone follow-up. Search a country or enter a custom +code.