Philips L12-3 Linear Array Ultrasound Probe for HD11, HD11 XE, iU22 and iE33 Systems – High Resolution Vascular and Small Parts Transducer

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
Product Overview
The Philips L12-3 is a broadband linear array ultrasound transducer designed for high-resolution vascular, small parts, breast, musculoskeletal, and superficial imaging applications. With a frequency range of 3–12 MHz, the probe delivers excellent near-field detail while maintaining adequate penetration for a wide variety of clinical examinations.
Engineered for Philips HD11, HD11 XE, iU22, and iE33 ultrasound systems, the L12-3 provides outstanding image quality for routine diagnostic imaging and Doppler studies. The linear array architecture produces a rectangular field of view that is particularly well suited for vascular assessments, thyroid imaging, breast examinations, tendon evaluations, and ultrasound-guided procedures.
The transducer supports advanced imaging technologies available on compatible Philips platforms, including B-Mode, Color Doppler, Power Doppler, Pulsed Wave Doppler, Tissue Harmonic Imaging, SonoCT compound imaging, and XRES adaptive image processing. These technologies contribute to improved tissue visualization and enhanced diagnostic confidence.
The Philips L12-3 remains one of the most commonly used Philips linear probes for radiology, vascular laboratories, breast imaging centers, orthopedic clinics, and general ultrasound departments.
Key Features
- Broadband linear array technology
- Frequency range of 3–12 MHz
- High-resolution superficial imaging
- Excellent vascular imaging capability
- Optimized for breast and thyroid examinations
- Color Doppler support
- Power Doppler support
- Pulsed Wave Doppler support
- Tissue Harmonic Imaging
- SonoCT compound imaging
- XRES image enhancement
- Suitable for ultrasound-guided procedures
Clinical Applications
Vascular Imaging
- Carotid artery examinations
- Peripheral arterial studies
- Venous Doppler imaging
- AV fistula assessment
- Vascular intervention guidance
Small Parts Imaging
- Thyroid examinations
- Parathyroid evaluation
- Lymph node assessment
- Salivary gland imaging
Breast Imaging
- Breast lesion evaluation
- Breast ultrasound screening
- Follow-up examinations
- Biopsy guidance
Musculoskeletal Imaging
- Tendon assessment
- Ligament evaluation
- Joint imaging
- Sports medicine applications
- Soft tissue examinations
Interventional Procedures
- Ultrasound-guided injections
- Biopsy guidance
- Vascular access procedures
Compatible Ultrasound Systems
Confirmed Compatible Systems
- Philips HD11
- Philips HD11 XE
- Philips iU22
- Philips iE33
- Selected HD Series platforms
Connector Platform
- Philips Large Connector
Not Compatible
- Philips EPIQ Series
- Philips Affiniti Series
- Philips CX30
- Philips CX50
- Philips Compact Connector Systems
- Philips ClearVue Series
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | Philips L12-3 |
| Probe Type | Linear Array |
| Frequency Range | 3 – 12 MHz |
| Applications | Vascular, Breast, MSK, Small Parts |
| Imaging Modes | B-Mode, Color Doppler, Power Doppler, PW Doppler, Harmonic Imaging |
| Connector Type | Philips Large Connector |
| Compatible Systems | HD11, HD11 XE, iU22, iE33 |
| Condition | Original Used |
| Testing Status | Fully Tested |
| Warranty | 60 Days |
Testing Procedure
Every Philips L12-3 probe undergoes comprehensive inspection and performance verification before shipment.
Testing includes:
- Crystal element integrity testing
- Uniformity testing
- B-mode image quality verification
- Color Doppler testing
- PW Doppler testing
- Connector inspection
- Cable and strain relief inspection
- Acoustic lens inspection
- Housing condition evaluation
- System recognition verification
Real testing images and videos can be provided upon request.
Warranty Information
- Fully tested and functional
- 60-day warranty
- Secure export packaging
- Worldwide shipping available
- DHL, FedEx, and UPS shipping options
- Typical delivery time: 2–5 business days
Why Choose Us
- Specialized supplier of ultrasound probes and replacement parts
- Extensive inventory of Philips transducers
- Professional testing procedures
- Fast worldwide shipping
- Competitive pricing
- Responsive customer support
- Real testing images and videos available before shipment
FAQ
Is this an original Philips probe?
Yes. This is an original Philips L12-3 linear array ultrasound transducer.
Which systems are compatible with the L12-3?
The probe is commonly used with Philips HD11, HD11 XE, iU22, and iE33 systems.
What are the primary applications?
The L12-3 is designed for vascular, breast, thyroid, musculoskeletal, and superficial imaging applications.
Does the probe support Doppler imaging?
Yes. The probe supports Color Doppler, Power Doppler, and Pulsed Wave Doppler modes on compatible systems.
Can you provide testing images before shipment?
Yes. Real testing images and videos are available upon request.
More from Probesources









More in Ultrasound Transducer






Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.
Ultrasound Transducer Buying Guide 2026: New vs Refurbished, Brand Comparison & What to Check Before You Buy
New vs refurbished ultrasound probes: GE, Philips, Siemens, Samsung compared. Covers compatibility, repair costs, and supplier verification.