Samsung L5-13IS Linear Array Ultrasound Probe for HERA, RS and HS Series Systems – Vascular, Small Parts, MSK and Breast Imaging

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
Product Overview
The Samsung L5-13IS is a premium linear array ultrasound transducer developed for vascular, breast and musculoskeletal imaging.
Its high-frequency bandwidth delivers excellent near-field resolution, making it ideal for evaluating superficial structures and vascular anatomy.
Key Benefits
✓ High-frequency imaging
✓ Excellent superficial tissue resolution
✓ Superior vascular visualization
✓ Ideal for breast imaging
✓ Excellent MSK performance
✓ High-quality Color Doppler sensitivity
✓ Reliable daily clinical workflow
Common Customer Pain Points
When purchasing a replacement Samsung L5-13IS, buyers are usually concerned about:
High-risk issues include:
- Crystal element dropout
- Poor image uniformity
- Weak Color Doppler sensitivity
- Cable fatigue damage
- Lens wear or delamination
- Connector communication failures
- Probe recognition errors
- Housing cracks
- Image artifacts
- Unexpected clinical downtime
Comprehensive Testing Before Shipment
Every Samsung L5-13IS undergoes complete inspection and operational verification before shipment.
Testing Includes
| Inspection Item | Verification |
|---|---|
| Crystal Performance | Fully Tested |
| B-Mode Imaging Quality | Verified |
| Color Doppler Function | Tested |
| PW Doppler Function | Verified |
| Image Uniformity | Checked |
| Near-Field Resolution | Tested |
| Cable Condition | Inspected |
| Connector Integrity | Verified |
| Probe Recognition | Tested |
| Overall Functionality | 100% Operational |
Before shipment, customers receive:
✓ Real testing images
✓ Live testing videos
✓ Functional verification confirmation
Clinical ApplicationsVascular Imaging
- Carotid artery examinations
- Peripheral vascular studies
- Venous mapping
- Deep vein thrombosis evaluation
Small Parts Imaging
- Thyroid assessment
- Parathyroid evaluation
- Lymph node imaging
- Soft tissue examinations
Breast Imaging
- Breast lesion assessment
- Screening support
- Interventional guidance
Musculoskeletal Imaging
- Tendon evaluation
- Ligament assessment
- Joint examinations
- Sports medicine applications
Pediatrics
- Superficial pediatric imaging
- Neonatal soft tissue examinations
Compatible Samsung Ultrasound Systems
Common compatible systems include:
- Samsung HERA W10
- Samsung HERA W9
- Samsung HERA I10
- Samsung RS85 Prestige
- Samsung RS80A
- Samsung RS80 Evo
- Samsung HS70A
- Samsung HS60
- Samsung V8
- Samsung V7
⚠️ Compatibility should always be verified according to software version and system configuration.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Samsung L5-13IS |
| Brand | Samsung Medison |
| Probe Type | Linear Array Transducer |
| Array Type | Linear Array |
| Frequency Range | 5 – 13 MHz |
| Applications | Vascular, Breast, MSK, Small Parts |
| Imaging Modes | B-Mode, Harmonic Imaging, Color Doppler, Power Doppler, PW Doppler |
| Clinical Specialty | Vascular & Superficial Imaging |
| Compatible Systems | HERA, RS, HS, V Series |
| Condition | Original Used |
| Testing Status | 100% Fully Tested |
| Warranty | 60 Days |
| Return Policy | 7-Day Return or Exchange |
| Delivery Time | 2–4 Business Days |
| Shipping Method | DHL / FedEx / UPS |
| Packaging | Professional Medical Export Packaging |
Why the Samsung L5-13IS Is Popular
| Clinical Requirement | L5-13IS Advantage |
|---|---|
| Vascular Imaging | Excellent Doppler sensitivity |
| Breast Imaging | High-resolution detail |
| Thyroid Imaging | Outstanding superficial resolution |
| MSK Studies | Precise tendon visualization |
| Small Parts | Exceptional image clarity |
| Daily Workflow | Reliable and durable performance |
The Samsung L5-13IS is widely used because it combines excellent superficial imaging quality, strong Doppler performance and broad clinical versatility for vascular and small-parts applications.
Difference Between L5-13IS and LA3-16A
| Feature | L5-13IS | LA3-16A |
|---|---|---|
| Frequency Range | 5–13 MHz | 3–16 MHz |
| Probe Type | Linear Array | High-Frequency Linear |
| Vascular Imaging | Excellent | Excellent |
| Breast Imaging | Excellent | Excellent |
| Deep Structure Penetration | Better | Moderate |
| Superficial Resolution | Excellent | Superior |
The L5-13IS offers a balance between penetration and resolution, while the LA3-16A emphasizes ultra-high-resolution superficial imaging.
More from Probesources









More in Ultrasound Transducer
Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.
Ultrasound Transducer Buying Guide 2026: New vs Refurbished, Brand Comparison & What to Check Before You Buy
New vs refurbished ultrasound probes: GE, Philips, Siemens, Samsung compared. Covers compatibility, repair costs, and supplier verification.


