Samsung CS1-4 Convex Ultrasound Probe for H60 and H60A Systems – Abdominal, OB/GYN and General Imaging Applications

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
Product Overview
The Samsung CS1-4 is a low-frequency curved array transducer optimized for deep abdominal and obstetric imaging.
Its wide bandwidth and excellent penetration capability make it a standard probe for routine clinical examinations on Samsung H60 series ultrasound systems.
Key Benefits
✓ Excellent deep penetration
✓ High-quality abdominal imaging
✓ Reliable OB/GYN examinations
✓ Wide field of view
✓ Stable Doppler performance
✓ Durable clinical design
✓ Optimized for daily workflow
Common Customer Pain Points
When purchasing a replacement Samsung CS1-4, buyers are usually concerned about:
High-risk issues include:
- Crystal element dropout
- Uneven image brightness
- Poor penetration depth
- Color Doppler failure
- Cable fatigue damage
- Lens wear or delamination
- Connector communication issues
- Probe recognition errors
- Housing cracks
- Unexpected clinical downtime
Comprehensive Testing Before Shipment
Every Samsung CS1-4 undergoes complete inspection and operational verification before shipment.
Testing Includes
| Inspection Item | Verification |
|---|---|
| Crystal Performance | Fully Tested |
| B-Mode Imaging Quality | Verified |
| Color Doppler Function | Tested |
| Power Doppler Function | Tested |
| PW Doppler Function | Verified |
| Penetration Performance | Tested |
| Image Uniformity | Checked |
| Connector Integrity | Inspected |
| Probe Recognition | Tested |
| Overall Functionality | 100% Operational |
Before shipment, customers receive:
✓ Real testing images
✓ Air-scan verification
✓ Functional testing videos
✓ Operational confirmation
Clinical ApplicationsAbdominal Imaging
- Liver examinations
- Gallbladder assessment
- Kidney imaging
- Pancreatic studies
- Spleen evaluation
Obstetrics
- Routine pregnancy examinations
- Fetal growth monitoring
- Prenatal screening
- Obstetric assessments
Gynecology
- Pelvic examinations
- Uterine assessment
- Ovarian imaging
General Imaging
- Abdominal screening
- Emergency ultrasound
- Routine diagnostic examinations
Compatible Samsung Ultrasound Systems
Common compatible systems include:
- Samsung H60
- Samsung H60A
- Samsung HS50
- Selected Samsung HS Series platforms
⚠️ Compatibility should always be verified according to probe connector type and software version.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Samsung CS1-4 |
| Brand | Samsung Medison |
| Probe Type | Curved Array / Convex Transducer |
| Array Type | Convex Array |
| Frequency Range | 1 – 4 MHz |
| Applications | Abdomen, OB, GYN, General Imaging |
| Imaging Modes | B-Mode, Harmonic Imaging, Color Doppler, Power Doppler, PW Doppler |
| Field of View | Wide Convex Field |
| Compatible Systems | H60, H60A, Selected HS Series |
| Condition | Original Used |
| Testing Status | 100% Fully Tested |
| Warranty | 60 Days |
| Return Policy | 7-Day Return or Exchange |
| Delivery Time | 2–4 Business Days |
| Shipping Method | DHL / FedEx / UPS |
| Packaging | Professional Medical Export Packaging |
Why the Samsung CS1-4 Is Popular
| Clinical Requirement | CS1-4 Advantage |
|---|---|
| Deep Abdominal Imaging | Excellent penetration |
| Routine OB Exams | Reliable fetal assessment |
| General Imaging | Versatile applications |
| Doppler Studies | Stable performance |
| Daily Clinical Workflow | Durable and dependable |
| H60 Users | Standard OEM probe |
The Samsung CS1-4 is widely used because it provides dependable image quality, deep penetration and broad clinical versatility for everyday abdominal and obstetric examinations.
Difference Between CS1-4 and C2-5
| Feature | CS1-4 | C2-5 |
|---|---|---|
| Frequency Range | 1–4 MHz | 2–5 MHz |
| Penetration | Higher | High |
| Resolution | Moderate | Better |
| Abdominal Imaging | Excellent | Excellent |
| OB/GYN Imaging | Excellent | Excellent |
| Platform | H60 / HS Series | SonoAce R Series |
| Clinical Positioning | Deep Imaging | General Imaging |
The CS1-4 is optimized for deeper penetration on H60-series systems, while the C2-5 offers a slightly higher frequency range with improved resolution for general imaging applications.
More from Probesources









More in Ultrasound Transducer
Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.
Ultrasound Transducer Buying Guide 2026: New vs Refurbished, Brand Comparison & What to Check Before You Buy
New vs refurbished ultrasound probes: GE, Philips, Siemens, Samsung compared. Covers compatibility, repair costs, and supplier verification.


