Philips S7-3t 2D TEE Ultrasound Transducer Probe for iU22 and iE33 Systems – Transesophageal Echocardiography Probe

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
Product Overview
The Philips S7-3t is a premium transesophageal echocardiography (TEE) transducer specifically designed for advanced cardiovascular imaging on Philips iU22 and iE33 ultrasound systems. As one of Philips' most widely used 2D TEE probes, the S7-3t provides outstanding image quality, excellent penetration, and reliable Doppler performance for comprehensive cardiac assessment.
Utilizing broadband sector array technology with an operating frequency range of 3–7 MHz, the S7-3t delivers detailed visualization of cardiac chambers, heart valves, ventricular function, atrial structures, and blood flow dynamics. The probe is designed to acquire high-resolution images from within the esophagus, enabling clinicians to obtain diagnostic information that may not be achievable with conventional transthoracic echocardiography.
The transducer supports a complete range of cardiac imaging modes including 2D imaging, Color Doppler, steerable Pulse Wave Doppler, Continuous Wave Doppler, harmonic imaging, XRES image enhancement, and M-mode imaging. These advanced capabilities make the probe suitable for routine diagnostic TEE examinations, intraoperative cardiac monitoring, structural heart interventions, congenital heart disease evaluation, and critical care cardiac assessment.
The S7-3t is commonly used in cardiac surgery suites, catheterization laboratories, intensive care units, and echocardiography departments. Its proven reliability and excellent imaging performance have made it a preferred choice for cardiologists, anesthesiologists, and cardiac surgeons worldwide. The probe is suitable for both adult and pediatric TEE examinations in patients weighing more than 3.5 kg.
Key Features
- Dedicated transesophageal echocardiography (TEE) transducer
- Broadband sector array technology
- 3–7 MHz operating frequency range
- High-resolution cardiac imaging
- Adult and pediatric TEE applications
- Color Doppler support
- Steerable Pulse Wave Doppler
- Continuous Wave Doppler capability
- Harmonic imaging technology
- XRES image enhancement
- M-mode imaging support
- Fully tested before shipment
Clinical Applications
Transesophageal Echocardiography (TEE)
- Comprehensive cardiac assessment
- Diagnostic TEE examinations
- Cardiac chamber evaluation
- Valve function analysis
Cardiac Surgery
- Intraoperative monitoring
- Valve repair procedures
- Valve replacement surgery
- Coronary artery bypass surgery
Structural Heart Procedures
- Left atrial appendage evaluation
- Septal defect assessment
- Device placement guidance
- Interventional cardiology procedures
Adult Cardiology
- Ventricular function assessment
- Endocarditis evaluation
- Cardiac source of embolism investigation
- Hemodynamic monitoring
Pediatric Cardiology
- Congenital heart disease assessment
- Pediatric TEE examinations
- Postoperative cardiac follow-up
Critical Care Imaging
- ICU cardiac monitoring
- Emergency cardiac assessment
- Hemodynamic evaluation
Compatible Ultrasound Systems
Confirmed Compatible Systems
- Philips iU22
- Philips iE33
Additional Compatible Platforms
- Selected Philips CX50 TEE configurations
- Selected Philips EPIQ cardiovascular systems
- Selected Philips Affiniti cardiovascular systems
Probe Category
- Transesophageal Echocardiography (TEE) Probe
Not Compatible
- Philips ClearVue Series
- Philips HD5
- Philips HD7
- Standard transthoracic probe ports
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | Philips S7-3t |
| Probe Type | TEE Transducer |
| Array Type | Sector Array |
| Frequency Range | 3 – 7 MHz |
| Number of Elements | 48 |
| Field of View | 90° |
| Applications | Adult and Pediatric TEE |
| Imaging Modes | 2D, Color Doppler, PW Doppler, CW Doppler, Harmonic Imaging, XRES, M-Mode |
| Connector Type | TEE Connector |
| Compatible Systems | iU22, iE33 |
| Condition | Original Used |
| Testing Status | Fully Tested |
| Warranty | 60 Days |
The S7-3t features a 48-element sector array with a 90° field of view and is designed for adult and pediatric TEE applications.
Testing Procedure
Every Philips S7-3t probe undergoes comprehensive inspection and functional verification before shipment.
Testing includes:
- TEE tip inspection
- Crystal element testing
- B-mode image quality verification
- Color Doppler testing
- PW Doppler testing
- CW Doppler testing
- Articulation mechanism verification
- Steering control testing
- Connector inspection
- Cable inspection
- Housing integrity inspection
- System recognition verification
Real testing images and videos are available upon request.
Warranty Information
- Fully tested and functional
- 60-day warranty
- Secure export packaging
- Worldwide shipping available
- DHL, FedEx, and UPS delivery options
- Typical delivery time: 2–5 business days
Why Choose Us
- Specialized supplier of ultrasound probes and replacement parts
- Extensive inventory of Philips cardiovascular transducers
- Professional TEE probe testing procedures
- Fast worldwide shipping
- Responsive technical support
- Competitive pricing
- Real testing images and videos available before shipment
FAQ
Is this an original Philips TEE probe?
Yes. This is an original Philips S7-3t transesophageal echocardiography transducer.
Is the probe fully tested?
Yes. All imaging functions, Doppler functions, articulation controls, and system recognition are verified before shipment.
Can you provide test images before shipment?
Yes. Real testing images and videos can be supplied upon request.
Do you offer warranty?
Yes. A 60-day warranty is included.
What is the primary application of the S7-3t?
The S7-3t is designed for adult and pediatric transesophageal echocardiography, intraoperative cardiac monitoring, and advanced cardiovascular imaging.
More from Probesources









More in Ultrasound Transducer
Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.
Ultrasound Transducer Buying Guide 2026: New vs Refurbished, Brand Comparison & What to Check Before You Buy
New vs refurbished ultrasound probes: GE, Philips, Siemens, Samsung compared. Covers compatibility, repair costs, and supplier verification.