Philips S12-4 Cardiac Ultrasound Probe for HD11, HD15, iU22 and iE33 Systems – Large Connector Sector Array Transducer

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
Product Overview
The Philips S12-4 is a premium broadband sector array transducer specifically designed for pediatric cardiology, neonatal cardiac imaging, and neonatal cranial ultrasound applications. Featuring an extended operating frequency range of 4–12 MHz, the probe delivers exceptional spatial resolution while maintaining sufficient penetration for detailed cardiac and neonatal examinations.
Unlike traditional adult cardiac probes that prioritize penetration, the S12-4 is optimized for imaging smaller anatomical structures with remarkable clarity. This makes it particularly valuable in pediatric echocardiography, congenital heart disease assessment, neonatal intensive care units (NICU), and specialized pediatric cardiac centers. The high-frequency design allows clinicians to visualize cardiac chambers, ventricular septa, valves, and blood flow patterns with excellent detail.
The transducer supports a comprehensive range of advanced imaging modes, including 2D imaging, Color Doppler, steerable Pulse Wave Doppler, Continuous Wave Doppler, High PRF Doppler, Tissue Doppler Imaging, harmonic imaging, M-mode, and M-mode Tissue Doppler. These capabilities provide clinicians with a complete solution for evaluating cardiac anatomy, ventricular function, valvular performance, and hemodynamic status.
Widely utilized on Philips premium ultrasound platforms, the S12-4 has become a trusted transducer for pediatric cardiologists, neonatal specialists, and sonographers who require outstanding image quality and diagnostic confidence in demanding clinical environments.
Key Features
- Broadband sector array technology
- Extended 4–12 MHz frequency range
- Optimized for pediatric cardiac imaging
- Excellent neonatal cardiac visualization
- Suitable for neonatal cranial imaging
- Supports Color Doppler and Spectral Doppler
- Tissue Doppler Imaging (TDI) capability
- Harmonic imaging support
- High PRF Doppler functionality
- Large Connector platform
- Fully tested before shipment
Clinical Applications
Pediatric Echocardiography
- Congenital heart disease assessment
- Cardiac chamber evaluation
- Valve function analysis
- Ventricular performance assessment
Neonatal Cardiology
- NICU cardiac examinations
- Newborn cardiac screening
- Structural heart evaluation
- Hemodynamic assessment
Pediatric Cardiology
- Follow-up cardiac examinations
- Doppler flow studies
- Cardiac function monitoring
Neonatal Head Imaging
- Cranial ultrasound examinations
- Neonatal brain assessment
- NICU neuroimaging
Advanced Doppler Applications
- Color Doppler Imaging
- Pulse Wave Doppler
- Continuous Wave Doppler
- Tissue Doppler Imaging
- High PRF Doppler
Compatible Ultrasound Systems
Confirmed Compatible Systems
- Philips HD11
- Philips HD11 XE
- Philips HD15
- Philips iU22
- Philips iE33
- Philips HD9 (configuration dependent)
Connector Platform
- Philips Large Connector
Not Compatible
- Philips CX30
- Philips CX50
- Philips S8-3 Compact Platform
- Philips Affiniti Series
- Philips EPIQ Series
- Philips ClearVue Series
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | Philips S12-4 |
| Probe Type | Sector Array |
| Array Type | Phased Array |
| Frequency Range | 4 – 12 MHz |
| Number of Elements | 96 |
| Field of View | 90° |
| Applications | Pediatric Cardiology, Neonatal Cardiology, Neonatal Head Imaging |
| Imaging Modes | 2D, Color Doppler, PW Doppler, CW Doppler, High PRF Doppler, TDI, Harmonic Imaging |
| Connector Type | Large Connector |
| Compatible Systems | HD11, HD11 XE, HD15, iU22, iE33 |
| Condition | Original Used |
| Testing Status | Fully Tested |
| Warranty | 60 Days |
Technical specifications sourced from Philips transducer documentation.
Testing Procedure
Every Philips S12-4 probe undergoes comprehensive inspection and performance verification before shipment.
Testing includes:
- Crystal element integrity verification
- B-mode image quality testing
- Color Doppler functionality testing
- PW Doppler verification
- CW Doppler verification
- Tissue Doppler testing
- Harmonic imaging verification
- Connector inspection
- Cable and strain relief inspection
- Housing condition evaluation
- System recognition verification
Real testing images and videos can be provided upon request.
Warranty Information
- Fully tested and functional
- 60-day warranty
- Secure export packaging
- Worldwide shipping available
- DHL, FedEx, and UPS delivery options
- Typical delivery time: 2–5 business days
Why Choose Us
- Specialized supplier of ultrasound probes and replacement parts
- Extensive inventory of Philips transducers
- Professional testing procedures
- Fast worldwide shipping
- Responsive customer support
- Competitive pricing
- Real testing images and videos available before shipment
FAQ
Is this an original Philips probe?
Yes. This is an original Philips S12-4 ultrasound transducer.
Is the probe fully tested?
Yes. All imaging modes and Doppler functions are verified before shipment.
Can you provide test images before shipment?
Yes. Real testing images and videos can be provided upon request.
Do you offer warranty?
Yes. A 60-day warranty is included.
What are the primary applications of the S12-4?
The S12-4 is primarily designed for pediatric cardiology, neonatal cardiac imaging, congenital heart disease assessment, and neonatal cranial ultrasound examinations.
Related Products
- Philips S8-3 Large Connector
- Philips S3-1 Large Connector
- Philips S4-1 Large Connector
- Philips S5-1 Large Connector
- Philips X7-2 Matrix Array
- Philips S12-4 Compact
More from Probesources









More in Ultrasound Transducer
Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.
Ultrasound Transducer Buying Guide 2026: New vs Refurbished, Brand Comparison & What to Check Before You Buy
New vs refurbished ultrasound probes: GE, Philips, Siemens, Samsung compared. Covers compatibility, repair costs, and supplier verification.