Samsung PN2-4 Phased Array Ultrasound Probe for HS40, HS30, HM70 EVO and MySono U6 Systems – Cardiac, Vascular and Abdominal Imaging

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
Product Overview
The Samsung PN2-4 is a dedicated phased-array probe designed for cardiovascular examinations requiring deep penetration and high frame-rate imaging.
Its compact footprint enables excellent acoustic access between the ribs, making it ideal for routine echocardiography and emergency cardiac assessment.
Key Benefits
✓ Excellent cardiac imaging performance
✓ Deep penetration capability
✓ Small sector footprint
✓ Reliable Doppler sensitivity
✓ Suitable for adult echocardiography
✓ Supports vascular examinations
✓ Proven clinical reliability
Common Customer Pain Points
When purchasing a replacement Samsung PN2-4, buyers are usually concerned about:
High-risk issues include:
- Crystal element dropout
- Weak color Doppler sensitivity
- Sector image artifacts
- Cable fatigue damage
- Lens wear
- Connector communication failure
- Probe recognition errors
- Housing cracks
- Poor cardiac image quality
- Unexpected clinical downtime
Comprehensive Testing Before Shipment
Every Samsung PN2-4 undergoes complete inspection and operational verification before shipment.
Testing Includes
| Inspection Item | Verification |
|---|---|
| Crystal Performance | Fully Tested |
| B-Mode Imaging Quality | Verified |
| Color Doppler Function | Tested |
| PW Doppler Function | Tested |
| CW Doppler Function | Tested |
| Cardiac Imaging Quality | Verified |
| Image Uniformity | Checked |
| Connector Integrity | Inspected |
| Probe Recognition | Tested |
| Overall Functionality | 100% Operational |
Before shipment, customers receive:
✓ Real testing images
✓ Live testing videos
✓ Functional verification confirmation
Clinical ApplicationsCardiology
- Adult echocardiography
- Cardiac chamber assessment
- Valve evaluation
- Cardiac function analysis
Pediatric Cardiology
- Congenital heart disease assessment
- Pediatric cardiac examinations
Vascular Imaging
- Doppler vascular studies
- Peripheral vessel assessment
Abdominal Imaging
- FAST examinations
- General abdominal assessment
- Emergency medicine applications
The PN2-4 is commonly used in cardiac, abdominal and vascular imaging applications.
Compatible Samsung Ultrasound Systems
Common compatible systems include:
- Samsung HS40
- Samsung HS30
- Samsung HM70 EVO
- Samsung MySono U6
- Samsung PT60A
These systems are listed in Samsung-related compatibility databases and HS40 probe documentation.
⚠️ Compatibility should always be verified according to software version and connector configuration.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Samsung PN2-4 |
| Brand | Samsung Medison |
| Probe Type | Phased Array Transducer |
| Array Type | Sector / Phased Array |
| Frequency Range | 2 – 4 MHz |
| Applications | Cardiac, Abdominal, Vascular |
| Imaging Modes | B-Mode, M-Mode, Color Doppler, PW Doppler, CW Doppler |
| Footprint | Small Cardiac Footprint |
| Compatible Systems | HS40, HS30, HM70 EVO, MySono U6, PT60A |
| Condition | Original Used |
| Testing Status | 100% Fully Tested |
| Warranty | 60 Days |
| Return Policy | 7-Day Return or Exchange |
| Delivery Time | 2–4 Business Days |
| Shipping Method | DHL / FedEx / UPS |
| Packaging | Professional Medical Export Packaging |
Why the Samsung PN2-4 Is Popular
| Clinical Requirement | PN2-4 Advantage |
|---|---|
| Adult Echocardiography | Excellent cardiac access |
| Deep Imaging | Strong penetration |
| Emergency Ultrasound | Fast acquisition |
| Cardiac Doppler | Reliable flow assessment |
| Portable Systems | Broad compatibility |
| Daily Clinical Use | Proven durability |
The PN2-4 is one of Samsung's most widely used phased-array probes because it combines strong cardiac imaging performance with compatibility across portable and cart-based ultrasound platforms.
Difference Between PN2-4 and SP3-8
| Feature | PN2-4 | SP3-8 |
|---|---|---|
| Frequency Range | 2–4 MHz | 3–8 MHz |
| Penetration | Higher | Moderate |
| Adult Cardiology | Excellent | Excellent |
| Pediatric Cardiology | Good | Better |
| Abdominal Imaging | Better | Limited |
| Near-Field Resolution | Good | Better |
The PN2-4 is optimized for deeper adult cardiac and abdominal examinations, while the SP3-8 provides higher frequency imaging for pediatric and superficial cardiac applications.
More from Probesources









More in Ultrasound Transducer






Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.
Ultrasound Transducer Buying Guide 2026: New vs Refurbished, Brand Comparison & What to Check Before You Buy
New vs refurbished ultrasound probes: GE, Philips, Siemens, Samsung compared. Covers compatibility, repair costs, and supplier verification.