Siemens Definition Flash Stellar Detector CT | 256-Slice Dual Source | P/N Straton Z Tubes | Software VB30A | OEM Maintained

Public supplier signals are visible here. Send an inquiry when the listing looks commercially fit.
Product Details
We are proud to present a premier 2015 SIEMENS Somatom Definition Flash 256-Slice CT Scanner, the industry benchmark for high-speed cardiac and pediatric imaging. Equipped with the revolutionary Stellar Detectors, this dual-source system minimizes electronic noise while maximizing diagnostic detail. This specific unit has been maintained exclusively under OEM Service Contract, ensuring peak operational integrity. Most notably, both X-ray tubes (Tube A & Tube B) were replaced in December 2024, offering the next owner a near-zero-hour dual-source solution for immediate clinical deployment.
Technical Specifications| Feature | Details |
| Manufacturer | SIEMENS Healthineers |
| Model | Somatom Definition Flash (Stellar Edition) |
| Year of Manufacture | 2015 |
| Slice Count | 256-Slice (Dual Source) |
| Software Level | Syngo VB30A-SP01 |
| Tube Status (A & B) | BOTH NEW - Installed December 2024 |
| Tube Scan Seconds | 44,478 sec (Ultra-low usage since exchange) |
| Gantry Scan Seconds | 4,331,394 sec |
| Detector Type | Stellar (Digital Photon Counting) |
| Cooling System | Roof-mounted Chiller (Air/Water) |
| Location | New Jersey, USA |
- Dual Source Advantage: Provides industry-leading temporal resolution (75ms), enabling high-quality cardiac scans at any heart rate without beta-blockers.
- Stellar Detector Technology: Digital signal conversion directly on the detector reduces cross-talk and delivers unmatched image quality in low-dose scenarios.
- Fresh Tube Investment: With both Straton Z tubes exchanged in late 2024, this system offers massive capital expenditure savings and long-term High-voltage stability.
- Advanced Licenses: Running VB30A, optimized for advanced dual-energy applications, CARE Dose4D, and high-pitch Flash spiral scanning.
More from A. Imaging Solutions
More in CT Scanner





Related editorial coverage
Ultrasound Transducer Common Failure Modes: How to Diagnose, Repair, or Replace
Ultrasound probe image problems? Diagnose lens delamination, oil leaks, cable damage & element dropout. Repair vs replace framework + find repair services on MedTrade.
AI Medical Imaging 2026: What the Clinical Data Actually Says
A data-driven look at AI radiology in 2026: the largest RCT ever conducted, why models crash across populations, and the ROI gap no one talks about.